Ask
Glue overflow of the second station product
Answer
Cause of failure: The relative position of station one and station two is not correct.
Processing method: set the station two correction.
Ask
Glue overflow of the second station product
Answer
Cause of failure: The trajectory setting is incorrect.
How to: Reset the layout.
Ask
Glue overflow of the second station product
Answer
Cause of failure: The needle is not installed correctly.
Treatment: Adjust the needle.
Ask
Servo abnormality
Answer
Cause of failure: Servo drive damage.
Handling method: Replace.
Ask
Servo abnormality
Answer
Cause of failure: Servo motor damage.
Handling method: Replace.
Ask
Servo abnormality
Answer
Cause of failure: The code line, power line is loose or damaged.
Processing method: check the coding line, power line.
Ask
Glue has bubbles
Answer
Treatment method: vacuum defoaming.
Ask
Glue has bubbles
Answer
Cause of failure: pipeline leakage.
How to handle: Recheck the tubing.